  1. Number:        A2TH081790U363
  2. Subject:       Set Maximum Packet Size Larger
  3. Date:          September 21, 1990
  4. - - - - - - - - - - - - - - - - - - - - - - - - - -
  5.  
  6. PROBLEM:       A customer was running NetWare 386 v3.1 on a Compaq 386
  7.                SystemPro.  The SystemPro had one of Compaq's 32 bit Token-
  8.                Ring cards in it.  
  9.  
  10.                The problem they had was that none of their AT machines
  11.                could copy a binary file to the file server.  They would get
  12.                a "Network error".  All of their XTs or microchannel
  13.                machines worked fine.  All of their workstations are running
  14.                at 16 Megabits.  The above problem only occurred with binary
  15.                files.
  16.  
  17. SOLUTION:      The solution to the problem was to set the "Maximum Receive
  18.                Physical Packet Size = 4202" in the STARTUP.NCF file.
  19.  